Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs

    Buy cheap Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs from wholesalers
     
    Buy cheap Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs from wholesalers
    • Buy cheap Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs from wholesalers

    Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs

    Ask Lasest Price
    Brand Name : Medpharm
    Model Number : MD-0.6V
    Certification : CE/SGS
    Price : Negotiation
    Payment Terms : T/T in advance, LC AT SIGHT
    Supply Ability : 10 pcs per month
    Delivery Time : 30 working days after received your payment
    • Product Details
    • Company Profile

    Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs


    Effluent Decontamination Veterinary Autoclave Bulk Steam Sterilization For Animal Labs


    Specification


    Model

    Chamber Size

    Overall Size

    Net Weight

    Steam

    Water

    Power

    W*H*D mm

    W*H*D mm

    Kg

    Kg/cycle

    Kg/cycle

    KVA

    MD-0.11V

    400*400*700

    1000*1800*1040

    650

    14

    15

    2

    MD-0.16V

    400*400*1000

    1000*1800*1340

    700

    16

    20

    2

    MD-0.20V

    400*400*1300

    1000*1800*1640

    750

    18

    25

    2

    MD-0.24V

    600*600*670

    1200*2000*1010

    800

    20

    30

    2

    MD-0.30V

    600*600*840

    1200*2000*1180

    850

    22

    35

    2

    MD-0.36V

    600*600*1000

    1200*2000*1340

    900

    25

    40

    2

    MD-0.45V

    600*600*1250

    1200*2000*1590

    980

    27

    50

    2

    MD-0.60V

    600*600*1670

    1200*2000*2010

    1100

    30

    60

    3


    Program Parameter

    Cycle name

    Further details

    Application

    Instruments/Tools

    3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.

    Solid materials to be sterilized:
    ●Packaged instruments
    ●Empty glass containers
    ●Empty metal containers
    Porous materials to be sterilized:
    ●Rubber articles

    Clothing

    3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.

    Materials to be sterilized from which air can’t be easily displaced
    ●Textile

    User Programmable

    All preset parameters can be reset; Multiple customized programs can be set and stored by user.

    Customized

    Test programs

    B-D Test

    3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.

    Test program

    Vacuum Leak Test

    Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

    Test program






















    Features


    • Piping, fittings, and valves are available in stainless steel.
    • All parts and components subject to repair are publicly available (i.e. non-proprietary) from open market sources, including controls, valves and fittings.
    • Safety relief valves and drains are integral to the plumbing configuration.
    • Baffled steam inlets minimize direct condensate on the load, reduce load wetting, and help
    • assure proper steam uniformity within the chamber.
    • Cabinet insulation retains heat and minimizes heat loss to the room. The sterilizer jacket and all steam service piping include a minimum 1" mineral wool-based insulation.
    • An integral waste water cooling function reduces discharge temperature to the Drain to less than 140°F (60°C).
    • On units equipped with steam generators, an pressure switch is included to back up the safety relief valve by automatically shutting down the steam generator if an over pressure condition exists.
    • Easy-to-read pressure gauges ensure simple and safe operation.
    • Other components required for the intended application may include a steam generator, vacuum pump, water ejector, etc. depending on the options chosen.

    Description

    Feature of the veterinary autoclave is the control of the sterilization phase according to a pressure signal, rather than temperature. Obviously, the temperature readout varies as a function of the position of the sensor, whilst the pressure is uniform throughout the chamber.


    However, process control is performed by reading in the chamber (and from inside the product) temperature signals whose match with the pressure value, as constantly verified by the controller, demonstrates that the autoclave is operating correctly.

    This principle, in saturated-steam conditions (when there is a two-way T/P correspondence) allows to obtain uniformities in sterilization temperature which are far better than the currently required level of ±1.0 °C.

    Applications

    • Un-Wrapped Goods
    • Wrapped Goods
    • Small volumes of Liquids
    • Rubbers and alumium caps


    Competitive Advantage

    Effluent Decontamination.
    Available on gravity and pre-vacuum units. Retains liquid effluent, if any, within the chamber for the duration of the sterilization cycle. Aerosol effluent passes through a 0.2 micron hydrophobic HEPA filter with >99.999% efficiency; the filter is located within the chamber and is sterilized in situ to eliminate the need for disposal after each cycle. The filter is easily replaced by the user when required without special tools or service personnel.

    Quality Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs for sale